Fire Alarm Phone Line Replacement (NFPA 72)
Cellular Fire Alarm Communicators, Dual Path Options and the Phone Line Requirements, for Organizations With Fire Panels in Many Buildings

AT&T copper shutoffs can start November 15, 2026 in parts of 18 states, and every fire panel on copper needs a new path its fire marshal and monitoring company accept. Send your panel list: the providers that fit price every building at once, and we negotiate.

Price My Fire Alarm Lines
Built for multi-building portfolios and 20+ lines Every panel priced by the providers that fit, at once No cost to you: the provider pays us
THE SHORT ANSWER
Fire alarm phone line replacement means moving a fire alarm panel’s reporting off copper phone lines and onto a communication path that NFPA 72 accepts, usually a cellular fire alarm communicator, often paired with a second path over the internet or radio. Under NFPA 72, a single path must be supervised at least every 60 minutes, and with two or more paths each one must be checked within 6 hours, according to the North Carolina State Construction Office’s summary of the 2013 edition. Since the 2016 edition, a dialer on two phone lines is no longer the only accepted design, as the Minnesota State Fire Marshal explains. Two parties must accept the new path in every building: the local fire marshal, as the authority having jurisdiction (AHJ), and the monitoring company that receives the signals. We put your panel list in front of the replacement providers that fit at the same time and negotiate the terms. The provider you choose pays us, so it costs you nothing.

With fire panels in a few buildings or a few hundred, the question is not whether one panel can come off copper. It is how to move every panel past two sign-offs per building before the copper is retired, without leaving a building unmonitored. Carrier notices arrive building by building. Since the FCC’s March 2026 order (FCC 26-19), every copper discontinuance application is granted automatically after 31 days unless the FCC acts, and industry analyses of the order put the gap between a customer notice and disconnection at as little as 90 days (source: vCom, July 16, 2026). That is not long to survey panel rooms and win two approvals per site. The copper retirement tracker lists which carriers are approved where; elevator phone line replacement and POTS line replacement cover the building’s other copper lines.

THE OLD DESIGN
2 lines
a traditional fire alarm dialer (DACT) reports over two copper phone lines
BUSINESS COPPER LEFT
8.6M
business switched access lines in the US at June 30, 2025, out of 15.0 million
AT&T SHUTOFFS CAN START
Nov 15, 2026
in wire centers across 18 states approved in January 2026
PUBLISHED REPLACEMENT RANGE
$40 to $60
per line per month for POTS over cellular; life-safety lines run at the top or above

Sources: Minnesota State Fire Marshal (DACT on two phone lines); FCC, Voice Telephone Services: Status as of June 30, 2025 (released May 2026); Broadband Breakfast, January 13, 2026 (AT&T approval); range source: AeroCom published 2026 price guide, August 6, 2026.

The clocks NFPA 72 sets for a fire alarm communication path
Two kinds of rule on one 0 to 24 hour scale: how fast a failed path must be reported (shorter is stricter) and how long backup power must last (longer is stricter)
SUPERVISION: LONGEST A FAILED PATH MAY GO UNREPORTED
One pathFailure reported at the monitoring company within
60 minutes
Two or more pathsFailure of any path reported within
6 hours
BACKUP POWER: MINIMUM RUNTIME FOR EQUIPMENT THE COMMUNICATOR SHARES
Standard requirementRouter, appliance or other shared gear
24 hours
By exceptionOnly with AHJ acceptance and a risk analysis
8 hours
A single path is checked six times as often. 360 minutes divided by 60. MCA calculation. With one path, nothing carries an alarm while it is down.
Backup power is a minimum. A router or appliance the communicator shares needs a full day of secondary power unless the fire marshal accepts 8 hours after a risk analysis.

Source: NFPA 72 sections 26.6.3.1.5, 26.6.3.1.6 and 26.6.3.1.15.1, as summarized by the North Carolina State Construction Office (2013 edition; confirm the edition your jurisdiction has adopted). Figures as of October 2026. Free to cite with a link to this page.

Replacing fire alarm lines across many buildings? Why talk to us before you call a provider
For organizations with multiple locations or 20 or more lines, whether that is three buildings or three hundred.
Quotes you can compare.
Every provider prices the same panel list: paths, battery, antennas where the panel room signal is weak, installation and monitoring. You compare real totals, not a headline price per line.
Not one vendor, alone.
Call one provider and you negotiate alone, and once you have asked it for pricing directly, it usually will not register an advisor on the deal. Send us the list before you sign anything or request quotes.
More than the carrier’s answer.
Your carrier’s own replacement is one option, not the only one. We put every site in front of the providers that fit at once.
No cost to you.
The provider you choose pays us, so it costs you nothing.
Send the building list and the panel at each one. Don’t have a full line list? Send what you have. A recent phone bill or a list of addresses is enough to start.
What happens next: you’ll hear back within 24 hours, we line up the providers that fit, and their engineers handle the site surveys. No calls needed on your end. If you have already spoken to one provider, tell us which; we can still run the rest of the market.

Do Fire Alarms Need a Phone Line?

No. A monitored fire alarm needs a communication path that NFPA 72 recognizes and the authority having jurisdiction (AHJ) accepts. A copper phone line is one such path, but not the only one. Cellular, radio and internet paths qualify when the equipment is listed for fire alarm service and the path is supervised on the code’s schedule. But when the copper under a dialer is cut and nothing replaces it, the building is no longer monitored.

The carrier is retiring the panel’s way of reaching the outside world, not the panel, and that touches three parties in every building: the carrier, the fire marshal who must accept the replacement, and the monitoring company whose receivers must understand it.

Fire Alarm Phone Line Requirements Under NFPA 72

NFPA 72, the National Fire Alarm and Signaling Code, sets the rules for how a fire alarm system reaches its supervising station. It is now performance-based: newer technologies are acceptable when they meet Chapter 26 (communications methods) and Chapter 10 (secondary power), as the Minnesota State Fire Marshal explains. The section numbers below are from the 2013 edition as North Carolina’s State Construction Office summarized it; each jurisdiction enforces the edition it has adopted, so confirm it with your AHJ.

RequirementWhat NFPA 72 saysWhat it means for the replacement
Communications integrity26.6.3.1.4The transmission technology and its communication path must be monitored for integrity.Whatever replaces the phone lines has to report its own failures to the monitoring company. A path that can fail silently does not qualify.
Single communication path26.6.3.1.5Permitted unless the AHJ, laws, codes or standards prohibit it. Supervised at intervals of no more than 60 minutes, with a failure reported at the supervising station within 60 minutes.One cellular communicator can be enough where the AHJ accepts a single path. For buildings where an outage would hurt most, price a second path too.
Multiple communication paths26.6.3.1.6Each path supervised within 6 hours, with a failure of any path reported within 6 hours.This is the dual path design, for example cellular plus the building’s internet. If one path fails, the other still carries alarms.
One technology, several paths26.6.3.1.7 and A.26.6.3.1.7A single technology may create multiple paths if the multiple path rules are met. With a single path, the risk of losing it for any period and any reason should be considered.A communicator that can use two cellular networks may count as two paths if it meets the multiple path rules. Ask the AHJ before you standardize on it.
Secondary power on shared equipment26.6.3.1.15.1Premises equipment the communicator shares needs 24 hours of secondary power. 8 hours is allowed only with AHJ acceptance and a risk analysis.A cellular appliance, router or switch in the path needs its own battery sized for a day, not just the fire panel.
Dialer (DACT) paths2016 editionA DACT can use one phone line plus a second path that is not a phone line: cellular, one-way radio, wireless mesh radio or IP.Keeping one copper line and adding cellular is allowed, but it is a bridge. The remaining line sits on the same retiring copper.
ApprovalThe AHJThe authority having jurisdiction, usually the fire marshal, accepts or rejects the replacement.Each building’s fire marshal signs off. For state buildings, North Carolina requires approval before installation.

Sources: NFPA 72 (2013 edition) sections as summarized by the North Carolina State Construction Office, dated December 15, 2022 (integrity, paths, secondary power, approval); Minnesota State Fire Marshal (2016 edition, DACT paths).

WHAT THAT MEANS
NFPA 72 does not name a product. It sets outcomes: a supervised path, a failure reported on time, backup power that lasts, and a fire marshal who accepts it. Two buildings across a city line can end up with different answers, so a portfolio plan is checked jurisdiction by jurisdiction. Healthcare buildings carry an extra wrinkle from the Life Safety Code, covered on our schools, hospitals and public buildings page.

What Is a Fire Alarm Communicator?

A fire alarm communicator is the device that sends a fire alarm panel’s alarm, supervisory and trouble signals to a supervising station, usually a monitoring company’s central station, which then notifies the fire department. The standard communicator was long a DACT (digital alarm communicator transmitter), a dialer that calls the central station over phone lines. A cellular fire alarm communicator does the same job over a cellular network. On burglar and intrusion panels the device is usually called a cellular alarm communicator.

DACT on phone lines

The traditional dialer, wired to two copper phone lines: the setup carriers are pulling the copper out from under.

Cellular fire alarm communicator

Sends signals over LTE or 5G, with no phone line. As a single path, it is supervised at least every 60 minutes, and the AHJ must accept it.

Dual path communicator

Two paths in one device, most often cellular plus the building’s internet. Each is checked within 6 hours, and either can carry an alarm if the other fails.

IP communicator

Reports over the building’s internet. IT has to agree to it, and the router and switch in the path need backup power too. See managed firewall services for the network edge it passes through.

Fire alarm radio communicator

One-way private radio, two-way RF multiplex or wireless mesh radio, where a radio network serves the area and the monitoring company receives it.

Line-emulating POTS replacement

An appliance that gives the existing dialer a dial tone over cellular. Ask how it is listed for fire alarm service and whether your AHJ and monitoring company accept it. Products are covered in POTS replacement providers compared.

Sources: Minnesota State Fire Marshal (DACT, one-way and mesh radio, IP paths); Prosper Fire Rescue (two-way RF multiplex); North Carolina State Construction Office (supervision intervals, IP on the owner’s network, backup power).

Fire Alarm Communication Path Options Compared

The right option for a given building depends on the AHJ, the signal at the panel, whether the fire alarm may use the building’s network, and what the monitoring company can receive.

SetupCopper still neededWhere it standsWhat to settle first
DACT on two phone linesThe traditional designTwo linesThe original design. The Minnesota State Fire Marshal notes these lines have become either unavailable or extremely expensiveWhen each line’s carrier notice arrives, and what the line costs once a contract ends
DACT on one phone line plus a second pathCellular, radio or IP as the second pathOne lineAllowed since the 2016 editionA bridge at best: the remaining line is on the same retiring copper
Single path cellular communicatorNoneAllowed unless the AHJ or local rules prohibit it; supervised at least every 60 minutesSignal strength at the panel, and the AHJ’s view of a single path
Dual path communicatorCellular plus IP, or cellular plus radioNoneMultiple path rules: each path checked within 6 hoursIT sign-off for the network path, and backup power for the router and switch
Radio communicatorOne-way private, two-way RF multiplex, meshNoneA recognized transmission methodWhether a radio network covers the site and the monitoring company receives it
Dialer on a VoIP lineNoneNot recommended for fire alarm signals by the Minnesota State Fire MarshalWhether the AHJ accepts it at all; see the VoIP section below

Sources: Minnesota State Fire Marshal; North Carolina State Construction Office (NFPA 72 2013 edition summary).

Single Path vs Dual Path Fire Alarm Communicators

A dual path fire alarm communicator sends signals over two independent paths, so one failure does not cut the building off. A single path communicator relies on one path and is supervised more tightly.

Single path

60 minutesThe longest a failed path may go unreported. One device, one monthly charge. Fits where the fire marshal accepts a single path and the survey shows a strong signal at the panel.

Dual path

6 hoursThe longest a failed path may go unreported, for each path. If one drops, the other still carries alarms. Fits high-rise, healthcare, campus and any building where the signal is marginal or the fire marshal asks for it.

WHAT THAT MEANS
A portfolio needs one standard, adjusted building by building: dual path wherever an outage would hurt most or the signal is marginal, single path only where the AHJ accepts it and the survey supports it. Setting the standard first lets every provider price the same design, which is what makes their quotes comparable.

Can a Fire Alarm Work on VoIP?

Not reliably, and it is not recommended. The Minnesota State Fire Marshal does not recommend VoIP for fire alarm signals: fire alarm data is not voice, and VoIP compression can alter the messages a dialer sends. An ordinary business VoIP line looks cheapest; check it most carefully with the AHJ.

One nuance: the 2010 edition of NFPA 72 added the managed facilities-based voice network (MFVN), a carrier-managed digital phone network that carries signals in real time, format unchanged. New Jersey’s Department of Community Affairs applied it. Its Bulletin 11-2 (April 2011) treated an MFVN that meets the listed conditions as functionally equivalent to the public phone network, required the fire subcode official to verify line seizure and signal transmission, and required eight hours of standby power for the MFVN equipment. That was one state’s guidance, not a national rule. If a provider proposes a voice line for a fire panel, ask whether it is an MFVN and ask the AHJ first. For other voice lines, VoIP is often right; see the POTS line replacement page.

THE TWO SIGN-OFFS

Who Approves a Fire Alarm Phone Line Replacement?

The authority having jurisdiction.
Usually the local fire marshal, sometimes a state agency for state buildings. The AHJ decides whether a single path is acceptable, whether a permit is needed, and whether the installed system passes. North Carolina’s State Construction Office, the AHJ for state buildings, requires approval before installation.
The monitoring company.
The central station has to receive the new communicator’s signals on its own receivers, for every account you move. North Carolina’s December 2022 guidance shows the cost of a mismatch: until the State Capitol Police receiving station could accept cellular calls, cellular alarms from state buildings would route to a private UL-listed station, at a monthly monitoring fee on top of each line’s cellular bill.
Two sign-offs, times every building.
Thirty buildings can mean thirty approvals from several fire marshals and a monitoring change on every account. We run the providers that fit and negotiate; the provider’s engineers survey and install, working with your fire alarm contractor and monitoring company. We do not install, monitor or sell hardware.
LOCAL RULES
Some jurisdictions go further. The Fire Marshal’s Office of Prosper Fire Rescue in Prosper, Texas, working from the 2019 edition of NFPA 72, permits only one-way private radio, two-way RF multiplex, cellular 4G or 5G, and IP-based systems. It does not permit copper phone lines for new installations, requires existing installations to be replaced when their phone lines no longer function, and requires the method to be listed to UL 864 (Prosper Fire Rescue, NFPA Supervising Station Communication Methods, Rev. 04-23). That is one town’s rule. Ask each AHJ in your portfolio for its written guidance before you standardize.

Cellular Coverage in Basements and Fire Panel Rooms

Fire alarm panels tend to live in basements, electrical rooms and fire command centers: concrete, below grade, often the weakest signal in the building. A cellular communicator is only as good as the signal where it is mounted, so every site needs a survey before anyone signs. North Carolina’s State Construction Office lists antennas or boosters, battery backup and obsolescence as networks move from 4G to 5G among the considerations for cellular. Elevator machine rooms raise the same question; our elevator phone line replacement guide covers that survey.

Signal at the panel

Measured where the communicator will hang, not in the lobby, for each network the device can use.

Antenna and cable run

An outside or upper-floor antenna can fix a weak room. The quote should say if one is needed and who runs the cable.

Backup power

The communicator and any router or appliance it shares, sized to the 24-hour rule unless the AHJ accepts less.

Network generation

Who pays for the swap when a network generation is retired.

Across a portfolio, the surveys sort buildings into three groups: strong signal, fixable with an antenna, and second path needed. That sort drives the design and the price, so it belongs in the quote request. Stores and bank branches raise the same question for alarm panels in back rooms; see retail and restaurants and banks and credit unions.

What Does Fire Alarm Phone Line Replacement Cost?

A published 2026 price guide puts POTS over cellular at about $40 to $60 per analog line per month. Some providers charge a flat $60; on appliance-based services the first line at a site runs about $60 and each additional line on the same appliance about $40, with up to four lines per appliance. Dual SIM service and battery backup are included by some providers and charged extra by others; the same guide suggests dual SIM for fire alarm and elevator lines where uptime is critical and calls battery backup a requirement for alarm lines that must work through an outage. Life-safety lines therefore price at the upper end of the range or above. The same guide says legacy copper lines with surcharges and fees often run over $100 per line per month.

An illustrative portfolio: 60 buildings, two fire alarm lines each
120 lines, monthly cost at the published per-line figures
Copper with surcharges and feesOver $100 per line
Over $12,000
Replacement, top of range$60 per line, where life-safety lines often land
$7,200
Replacement, bottom of range$40 per line
$4,800

MCA calculation: 60 buildings × 2 lines = 120 lines; 120 × $100 = $12,000, 120 × $60 = $7,200, 120 × $40 = $4,800 a month. Source for the per-line figures: AeroCom published 2026 price guide, August 6, 2026. Illustrative, not a quote. Figures as of October 2026.

WHAT THAT MEANS
At the top of the published range, the illustrative portfolio pays $7,200 a month against more than $12,000 on legacy copper: about $4,800 a month, or $57,600 a year. MCA calculation: ($12,000 − $7,200) × 12. Two things move the real number. First, a panel that used two phone lines may need one dual path communicator rather than two replacement lines, so every provider should price per panel as well as per line. Second, contract timing. After AT&T did not renew North Carolina’s state contract, sample tariff rates published by North Carolina’s state IT department listed a POTS line at $34.42 a month under the contract and $2,460.12 a month at the sample tariff rate from January 1, 2026. The state says sample rates may not reflect final pricing and exclude surcharges and fees, and they describe one customer’s contract, not a forecast of anyone else’s bill. They do show that the end of a contract can change a line’s price, so contract end dates belong in the plan. The POTS line replacement calculator runs the same arithmetic on your own line counts.
Send each building, its panel and its contract end date.
For organizations with multiple locations or 20 or more lines. Send it before contracts end and notices arrive: the providers that fit price every panel on the same design, and we negotiate the totals. Don’t have a full line list? A recent phone bill or a list of addresses is enough to start. The provider you choose pays us, so it costs you nothing.
Price My Fire Alarm Lines
THE ROLLOUT

Replacing Fire Alarm Phone Lines Across a Portfolio, Step by Step

1
Inventory every panel and every line.
For each building: where the panel is, how many lines it uses, the carrier, the monitoring company, the AHJ and the contract end date.
2
Put the dates in order.
Buildings with a carrier notice or an expiring contract go first; the rest fit around inspections and testing windows.
3
Survey the signal at every panel.
The provider’s engineers sort the buildings into strong signal, antenna needed, and second path needed.
4
Settle the design with each AHJ and the monitoring company.
Single or dual path, any permit, and written confirmation that the central station receives the new communicator, before installation.
5
Install and test in waves.
Group buildings by jurisdiction so each fire marshal sees one plan. Each account goes on test with the monitoring company, signals are confirmed end to end, and inspections are booked where required.
6
Cancel the copper last.
Only after the new path is accepted and tested. Then check the next invoice to be sure billing stopped.

Most buildings also carry elevator phones, alarm panels, fax, gates and call boxes. One project means one survey per building and one schedule. Owners and managers will find the per-building inventory on our property management page, and districts, campuses and health systems on schools, hospitals and public buildings.

Six Mistakes That Slow a Fire Alarm Line Replacement

Replacing one building at a time

Each call produces one answer for one building on one provider’s design, with no portfolio price.

Asking one provider for pricing first

Once you have asked a provider for pricing directly, it usually will not register an advisor on the deal, and you negotiate alone.

Assuming any cellular box is fit for fire

Fire alarm equipment has to be listed for that service, and some jurisdictions name the listing, such as UL 864. The AHJ and the monitoring company both must accept it.

Skipping the signal survey

A device that works in the lobby can fail in a basement panel room. Survey where the communicator will hang.

Forgetting the battery on shared gear

The 24-hour secondary power rule covers a router or appliance the communicator shares, not only the fire panel.

Canceling copper before acceptance

A panel with no working path is not monitored, and the fire marshal may require a fire watch until it is. Keep the old lines until the new path passes.

How We Place POTS Replacement

1

You send the line list

Locations, lines per location and what each runs (fire alarm, elevator, alarm panel, fax, gate or call box, ATM or payment terminal, voice), a recent invoice, carrier notice letters, contract end dates and each panel’s monitoring company. No full list yet? A recent phone bill or a list of addresses is enough to start.

2

We run the providers that fit, at once

The providers that fit your line types and locations see the same request on the same day, so the quotes compare panel by panel. Your carrier’s own replacement can be one of them.

3

The provider’s engineers survey the sites

Signal at each panel, antennas, power, and the design each AHJ and monitoring company will accept.

4

We negotiate and you sign

Price per line and per panel, equipment, installation, rollout schedule, support and term, settled while still negotiable. You sign with the provider you choose, on one contract and one bill where that fits.

5

The provider pays us

The provider you choose pays us, so it costs you nothing. More on how we work is on our about page.

Fire Alarm Phone Line Replacement: Frequently Asked Questions

Do fire alarms need a phone line?

No. A monitored fire alarm needs a communication path that NFPA 72 recognizes and the local authority having jurisdiction accepts, and a copper phone line is only one of them. Cellular, radio and IP communicators listed for fire alarm service can take its place, supervised on the code's schedule.

What is a fire alarm communicator?

It is the device that sends a fire alarm panel's alarm, supervisory and trouble signals to a supervising station, usually a monitoring company's central station. The traditional version is a DACT, a dialer that uses phone lines. Newer versions use cellular, radio or the internet.

What is a cellular fire alarm communicator?

It is a fire alarm communicator that sends signals over a cellular network instead of phone lines. Used as the only path, NFPA 72 requires it to be supervised at least every 60 minutes, and the AHJ must accept a single path. Paired with a second path such as IP, each path must be checked within 6 hours.

Why do fire alarms have two phone lines?

The traditional dialer, a DACT, reports over two phone lines so that one failed line does not cut the building off from its monitoring company. Under the 2016 edition of NFPA 72, a DACT can use one phone line plus a second path that is not a phone line, such as cellular, radio or IP. Newer communicators can replace both lines with no copper at all.

Can a fire alarm work on VoIP?

It is not recommended. The Minnesota State Fire Marshal advises against VoIP for fire alarm signals because its compression can alter the messages a dialer sends. A carrier's managed facilities-based voice network is treated differently under NFPA 72, so ask the AHJ before connecting any panel to a voice service.

What is a dual path fire alarm communicator?

It is a communicator that sends signals over two independent paths, most often cellular plus the building's internet connection. Under NFPA 72, each path must be supervised within 6 hours, and either path can carry an alarm if the other fails.

What are the NFPA 72 cellular communicator requirements?

The path must be monitored for integrity, a single path must be supervised at least every 60 minutes, and with multiple paths each must be checked within 6 hours. Shared premises equipment needs 24 hours of secondary power, or 8 hours with AHJ acceptance and a risk analysis. Those are the 2013 edition's rules as North Carolina's State Construction Office summarizes them; the local AHJ decides which edition applies and whether the installation is accepted, and some jurisdictions add rules of their own.

Who approves a fire alarm phone line replacement?

The authority having jurisdiction, usually the local fire marshal, accepts or rejects it, and the monitoring company must be able to receive the new signals. For state buildings in North Carolina, the State Construction Office must approve any replacement before it is installed. Ask each AHJ in a portfolio for its written guidance.

How much does a cellular fire alarm communicator cost?

A published 2026 price guide puts POTS over cellular at about $40 to $60 per line per month, and fire alarm lines land at the top of that range or above because of dual path, battery and monitoring needs. Equipment, antennas and installation are quoted per site. Ask for pricing per panel as well as per line, since one dual path communicator may replace two phone lines.

What if the cellular signal is weak in the fire panel room?

An outside or upper-floor antenna, a different cellular network, or a second path such as IP can solve it. The provider's site survey should measure the signal where the communicator will be mounted, before anyone signs.

When are fire alarm phone lines being shut off?

It depends on the carrier and the wire center. AT&T can begin discontinuing copper service in wire centers across 18 states starting November 15, 2026, and since the FCC's March 2026 order every discontinuance application is granted automatically after 31 days unless the FCC acts. Industry analyses of the order put the gap between a customer notice and disconnection at as little as 90 days.

Does Metro Colo Advisory install or monitor fire alarms?

No. We do not install communicators, monitor alarms or sell hardware. We put your line list in front of the replacement providers that fit and negotiate price and terms, and the provider's engineers survey and install, working with your fire alarm contractor and monitoring company.

What do you need from us to price our fire alarm lines?

The number of locations, the lines at each one and what each line runs, a recent invoice or the current monthly bill, any carrier notice letters, and contract end dates. For fire alarm lines, add the monitoring company for each building. If you do not have all of that yet, a recent phone bill or a list of addresses is enough to start, and you'll hear back within 24 hours.

Is this worth it for a single building?

Usually not through us. If you have one building and a couple of lines, your carrier's own replacement or your alarm company's communicator may be the simplest answer, and we will say so. Our service is built for organizations with multiple locations or 20 or more lines, and a company with a few buildings is a good fit.

Send Us Your Fire Alarm Line List

Don’t have a full line list? Send what you have. A recent phone bill or a list of addresses is enough to start. You’ll hear back within 24 hours, we line up the providers that fit, and their engineers handle the site surveys. No calls needed on your end. If you have one building and a couple of lines, your carrier’s own replacement or your alarm company’s communicator may be the simplest answer, and we will say so.

Send the list before you sign anything or request quotes.
For organizations with multiple locations or 20 or more lines. Your carrier’s replacement is one option; the providers that fit price every panel at once, and we negotiate the terms. The provider you choose pays us, so it costs you nothing.
Price My Fire Alarm Lines